PROBE - Linearized probe - Measuring bolt mounted on a ball bearing - Guiding is insensitive to any radial force exerted on the measuring bolt - Separate guiding from the housing so that the movement of the measuring bolt moves easily even if the probe is not clamped appropriately - Ø 8 mm probe housing, can be clamped over its entire length - The guides are effectively protected against penetration of liquids (oils) or solids (dust) by sealing bellows • MEASUREMENT - The measuring force can be adjusted by changing the spring (depending on model) - The measuring inserts can be replaced or exchanged
Hysteresis |
0,02 µm |
Standard |
DIN 32876 |
Max. perm. errors |
L in mm 0,2 + 2,4 x (L x L) µm 0,2 + 0,8 x L µm (with TESA interface) |
Repeatability |
0,01 µm |
Coefficient of linear expansion |
0,2 µm/°C |
Material |
Fixing shank: nickel plated Measuring bolt: stainless steel Protection bellow: Viton® Ball insert: tungsten carbide |
Dimensions |
Fixing shank: Ø 8 mm Insert thread: M2,5 Ball insert: Ø 3 mm Cable: 2 m Connector: 5p DIN45322 |
Degree of protection |
IP65 |
Weight |
Mobile weight: 6 g |
Remark(s) |
CAD files available on request Downloadable data sheets on www.TESAtechnology.com |
Included in delivery |
Probe Wrench Measurement report User manual Declaration of conformity |